{"id":4051,"date":"2026-07-15T09:33:38","date_gmt":"2026-07-15T07:33:38","guid":{"rendered":"https:\/\/www.tecnolab-srl.it\/?post_type=prodotti&#038;p=4051"},"modified":"2026-09-29T12:06:39","modified_gmt":"2026-09-29T10:06:39","slug":"intelligent-nitrogen-control","status":"publish","type":"prodotti","link":"https:\/\/www.tecnolab-srl.it\/en\/products\/intelligent-nitrogen-control\/","title":{"rendered":"Intelligent Nitrogen Control"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The nitrogen control system integrated into the R-Series, featuring advanced lambda probe technology, ensures extremely precise management of residual oxygen levels in PPM throughout the reflow soldering process.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks to certification issued by a DAkkS-accredited laboratory, the system guarantees maximum reliability and compliance with international standards.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-desc-2-font-size\">Certified Measurement Accuracy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Residual Oxygen Measurement Devices (DRSM) are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tested and calibrated by an independent, accredited laboratory<\/li>\n\n\n\n<li>Verified according to the most stringent tolerance requirements<\/li>\n\n\n\n<li>Compliant with the latest international standards<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This ensures that every measurement performed during the process is accurate, repeatable, and reliable.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-desc-2-font-size\">Long-Term Reliability<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Third-party certification confirms that:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measurement systems maintain high performance over time<\/li>\n\n\n\n<li>Recalibrated elements meet the highest quality standards<\/li>\n\n\n\n<li>Process control remains stable, even during intensive and extended production cycles<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading has-desc-2-font-size\">Continuous Monitoring and Easy Calibration<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The system provides:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Real-time monitoring of residual oxygen levels in PPM<\/li>\n\n\n\n<li>Fast, on-site calibration directly through the software<\/li>\n\n\n\n<li>Reduced machine downtime<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Additionally, the Calib_O2 software application further enhances the accuracy of measured values during operation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/www.tecnolab-srl.it\/wp-content\/uploads\/2025\/10\/immagine_1920x1080.jpg\" alt=\"illustrazione funzionamento della macchina Reflow \" class=\"wp-image-2100\" srcset=\"https:\/\/www.tecnolab-srl.it\/wp-content\/uploads\/2025\/10\/immagine_1920x1080.jpg 900w, https:\/\/www.tecnolab-srl.it\/wp-content\/uploads\/2025\/10\/immagine_1920x1080-300x169.jpg 300w, https:\/\/www.tecnolab-srl.it\/wp-content\/uploads\/2025\/10\/immagine_1920x1080-768x432.jpg 768w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The DAkkS-accredited laboratory is globally recognized as a:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Member of the European co-operation for Accreditation (EA)<\/li>\n\n\n\n<li>Participant in the International Laboratory Accreditation Cooperation (ILAC)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This ensures that all measurements are internationally recognized and accepted.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-desc-2-font-size\">Benefits for Your Production Process<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Improved soldering quality and process stability<\/li>\n\n\n\n<li>Reduced nitrogen consumption<\/li>\n\n\n\n<li>Precise control of process conditions<\/li>\n\n\n\n<li>Increased overall reliability of the SMT production line<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The nitrogen control system ensures extremely precise management of residual oxygen levels in PPM.<\/p>\n","protected":false},"author":2,"featured_media":4052,"comment_status":"closed","ping_status":"closed","template":"","famiglia":[57,63],"class_list":["post-4051","prodotti","type-prodotti","status-publish","has-post-thumbnail","hentry","famiglia-smt-machines","famiglia-smt-reflow-soldering-system"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/prodotti\/4051","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/prodotti"}],"about":[{"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/types\/prodotti"}],"author":[{"embeddable":true,"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/comments?post=4051"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/media\/4052"}],"wp:attachment":[{"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/media?parent=4051"}],"wp:term":[{"taxonomy":"famiglia","embeddable":true,"href":"https:\/\/www.tecnolab-srl.it\/en\/wp-json\/wp\/v2\/famiglia?post=4051"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}